- 当工作完成时
<2021-3-10 上午07时14分36,506秒 CST> <Notice> <Server> <BEA-002638> <Graceful shutdown was issued remotely from 192.168.223.100:17010.>
<2021-3-10 上午07时14分36,509秒 CST> <Notice> <WebLogicServer> <BEA-000396> <Server shutdown has been requested by weblogic.>
<2021-3-10 上午07时14分36,515秒 CST> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to SUSPENDING.>
<2021-3-10 上午07时14分36,529秒 CST> <Notice> <Cluster> <BEA-000163> <Stopping "async" replication service>
<2021-3-10 上午07时14分36,540秒 CST> <Notice> <HTTP> <BEA-101278> <There are no active sessions. The Web service is ready to suspend.>
<2021-3-10 上午07时14分36,566秒 CST> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to ADMIN.>
<2021-3-10 上午07时14分36,570秒 CST> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to SHUTTING_DOWN.>
<2021-3-10 上午07时14分36,637秒 CST> <Notice> <Log Management> <BEA-170037> <The log monitoring service timer has been stopped.>
<2021-3-10 上午07时14分41,969秒 CST> <Warning> <JMX> <BEA-149513> <JMX Connector Server stopped at service:jmx:iiop://192.168.223.101:13000/jndi/weblogic.management.mbeanservers.runtime.>
Stopping Derby server...
Derby server stopped.
<2021-3-10 上午07时14分44秒 CST> <INFO> <NodeManager> <The server 'cluServer3' with process id 73319 is no longer alive; waiting for the process to die.>
<2021-3-10 上午07时14分44秒 CST> <FINEST> <NodeManager> <Process died.>
<2021-3-10 上午07时14分44秒 CST> <INFO> <NodeManager> <Server was shut down normally>
<2021-3-10 上午07时14分44秒 CST> <FINEST> <NodeManager> <runMonitor returned, setting finished=true and notifying waiters>
- 立即强制关闭
<2021-3-10 上午07时43分44,799秒 CST> <Notice> <Server> <BEA-002638> <Force shutdown was issued remotely from 192.168.223.100:17010.>
<2021-3-10 上午07时43分44,799秒 CST> <Notice> <WebLogicServer> <BEA-000396> <Server shutdown has been requested by weblogic.>
<2021-3-10 上午07时43分44,838秒 CST> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to FORCE_SUSPENDING.>
<2021-3-10 上午07时43分44,853秒 CST> <Notice> <Cluster> <BEA-000163> <Stopping "async" replication service>
<2021-3-10 上午07时43分44,891秒 CST> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to ADMIN.>
<2021-3-10 上午07时43分44,897秒 CST> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to FORCE_SHUTTING_DOWN.>
<2021-3-10 上午07时43分44,922秒 CST> <Notice> <Log Management> <BEA-170037> <The log monitoring service timer has been stopped.>
三月 10, 2021 7:43:44 上午 weblogic.wsee.WseeCoreMessages logWseeServiceHalting
信息: 正在中断 Wsee 服务
<2021-3-10 上午07时43分45,263秒 CST> <Warning> <JMX> <BEA-149513> <JMX Connector Server stopped at service:jmx:iiop://192.168.223.101:13000/jndi/weblogic.management.mbeanservers.runtime.>
Stopping Derby server...
Derby server stopped.
<2021-3-10 上午07时43分46秒 CST> <INFO> <NodeManager> <The server 'cluServer3' with process id 39227 is no longer alive; waiting for the process to die.>
<2021-3-10 上午07时43分46秒 CST> <FINEST> <NodeManager> <Process died.>
<2021-3-10 上午07时43分46秒 CST> <INFO> <NodeManager> <Server was shut down normally>
<2021-3-10 上午07时43分46秒 CST> <FINEST> <NodeManager> <runMonitor returned, setting finished=true and notifying waiters>